A fully enclosed, steel-framed padel court system engineered with insulated sandwich panels  delivering year-round comfort, superior thermal performance, and a durable, weather-resistant structure.

Sandwich Padel exterior view

System Overview

This specification defines the design, engineering, fabrication, supply, installation, and quality control of a steel roof and enclosure system for padel courts located in Germany, executed by Unixpadel.

The System Includes

  • Primary and secondary steel structures (H-profiles)
  • Hot-dip galvanized steel components
  • Thermal insulated sandwich panel roof and façade
  • Glazed façade elements for natural daylight
  • Anchorage and foundation connection systems
  • Drainage and condensation control elements
  • Wind, snow and seismic resistant detailing
  • Maintenance and inspection access provisions
Sandwich Padel structural detail

Engineered for All Conditions

Every Unixpadel structure is calculated against the strictest European load conditions, ensuring safety and longevity across diverse climates.

  • Characteristic snow load: ≥ 1.50 kN/m² (150 kg/m²) on horizontal projection
  • Wind loads: According to NTC 2018 and Eurocode EN 1991-1-4, based on Germany wind zone
  • Seismic actions: Evaluated per EN 1998 / NTC 2018, where required by local authority
  • Temperature range: −20 °C to +60 °C
  • Execution class: Minimum EXC2 (EN 1090-2)
  • Deflection limits: L/250 general; stricter for roof panels to prevent ponding
Sandwich Padel interior court view

Premium Steel & Sandwich Panels

Стальная конструкция

  • Steel grade: S355 (EN 10025)
  • Profiles: H-profiles (columns and main beams)
  • Surface protection: Hot-dip galvanizing ≥ 85 μm (EN ISO 1461)

Bolting & Welding

  • Preloaded bolts EN 14399 / standard joints EN 15048
  • Stainless steel AISI 304 / 316 where exposed
  • Welding to EN ISO 3834-2; welders certified EN ISO 9606-1

Roof & Façade Performance

Panel Characteristics

  • Core material: PIR or PUR insulation
  • Thickness: 60–100 mm (project specific)
  • Thermal conductivity (λ): ≤ 0.022 W/mK
  • U-value, roof: ≤ 0.30 W/m²K
  • U-value, wall: ≤ 0.35 W/m²K

Fire, Acoustic & Durability

  • Fire reaction: EN 13501-1 — B-s2,d0
  • Sound insulation: Rw ≥ 25–30 dB
  • Air & water tightness: Tested per EN standards
  • Durability: UV, moisture & corrosion resistant
  • Standard: EN 14509 factory-made panels

Удостоверение

  • Маркировка CE (EN 14509)
  • Отчеты о тестировании тепловых характеристик
  • Сертификаты по классификации пожарной опасности
  • Документация по акустической и конденсационной стойкости

Структурная система

  • H-profile main frames with 3.0–5.0 m spacing
  • Secondary steel members support sandwich panels
  • Glazed façade zones for natural lighting
  • Integrated gutter and drainage system
  • Snow sliding & accumulation control
  • Maintenance access lines and anchor points
Sandwich Padel standards compliance

Full European Compliance

еврокоды

  • EN 1990 – Основы проектирования конструкций
  • EN 1991-1-3 / 1991-1-4 – Snow & wind actions
  • EN 1993 – Стальные конструкции
  • EN 1998 – Seismic design

Execution & Quality

  • EN 1090-1 / EN 1090-2 – CE marking & execution
  • EN ISO 3834-2 – Welding quality requirements
  • EN ISO 1461 – Hot-dip galvanizing
  • EN ISO 12944 – Долговечность и защита от коррозии

All documentation validated and signed by a licensed Italian structural engineer (Albo).

Sandwich Padel foundation work

Anchorage & Foundations

The connection between structure and substrate is engineered to transfer combined tension and shear forces safely into the foundation.

  • Анкеры, предназначенные для комбинированного растяжения и сдвига
  • Химические или механические анкеры, одобренные ETA
  • Installation per manufacturer instructions: drilling, cleaning, curing, torque control
  • Compliance with EAD 330232-00-0601
  • Reinforcement verified by non-destructive methods where required