A lighting set designed with the court
Eight MARGAY-200 LED floodlights on four poles light the whole 20 × 10 m playing area of the standard court. The layout was simulated on the court itself rather than picked from a table: 322 lx maintained average illuminance with a uniformity (U₀) of 0.73. That meets EN 12193 Class II for club competition.
Results on the playing area
| Measure | Result |
|---|---|
| Average illuminance (maintained) | 322 lx |
| Minimum / maximum | 234 / 433 lx |
| Uniformity U₀ (minimum / average) | 0.73 |
| Uniformity Ud (minimum / maximum) | 0.54 |
| Maintenance factor | 0.80 |
The result holds when the calculation grid is tightened or the beam changes, with the aiming kept as installed: U₀ 0.71 on a 0.5 m grid, 347 lx with an 80° beam and 300 lx with a 100° beam.
Against the lighting classes
| Class | Average | U₀ | This design |
|---|---|---|---|
| EN 12193 Class II (club competition) | 300 lx | 0.7 | Met |
| EN 12193 Class III (training) | 200 lx | 0.6 | Met |
The maintained average is 7 % above the Class II minimum of 300 lx.
What the set includes
- 4 poles with 2 MARGAY-200 floodlights each, 8 in total
- Floodlights aimed at 28.5° and 37.5°, without visors
- 200 W and 26,000 lm per floodlight; 6400 K, Ra > 80, 90° beam
- IP65 aluminium housing, full light in under 0.2 s, 2-year warranty
Power and energy use
The eight floodlights draw 1.6 kW together. At four hours a night, that is about 2,336 kWh a year.
These figures are calculated with approximate photometry (no LDT file is available) and are maintained values. Out-of-court play is not permitted with this pole layout. Final values must be confirmed by measurement on site.